Tecfi Concreto ® – HXE Concrete Screw

Tecfi Concrete Screw HXE01 Concreto® has now achieved European Technical Approval according to ETAG 001-Part 1 and Part 3, OPTION 1 and also Fire Resistance Certification according to Technical Report 020 in the class of duration of the fire Resistance R120.

ETA Option 1 ensures the use of HXE both in cracked and non-cracked concrete (classes C20/25 ÷ C50/60) for structural applications.

Brand: Tecfi


HXE01

CONCRETO®
Patented hexagonal flanged washer head with serration concrete screw, zinc plated, ETA-CE Opt.1 certified
Across Flats
Across Flats
Certified Product
Certified Product
More Info
More Info

      Item Code Screw size Pcs. per Box Pcs. per Carton
        Ø x Ls / t fix (mm)    
 

HXE 01 08 080 8 x 80 / 20 50 500
 

HXE 01 08 100 8 x 100 / 40 50 500
 

HXE 01 08 120 8 x 120 / 60 50 500
 

HXE 01 08 140 8 x 140 / 80 50 500
 

HXE 01 10 080 10 x 80 / 10 50 500
 

HXE 01 10 100 10 x 100 / 30 25 250
 

HXE 01 10 120 10 x 120 / 50 25 250
 

HXE 01 10 140 10 x 140 / 70 25 250
 

HXE 01 10 160 10 x 160 / 90 25 250
 

HXE 01 12 090 12 x 90 / 10 25 250
 

HXE 01 12 110 12 x 110 / 30 25 250
 

HXE 01 12 130 12 x 130 / 50 25 250
 

HXE 01 12 150 12 x 150 / 70 25 250
 

HXE 01 12 190 12 x 190 / 110 20 100
 

HXE 01 12 210 12 x 210 / 130 20 100
 

HXE 01 12 250 12 x 250 / 170 15 75
 

HXE 01 12 290 12 x 290 / 210 15 75

HXE 01 16 130 16 x 130 / 20 10 100

HXE 01 16 150 16 x 150 / 40 10 100

HXE 01 16 180 16 x 180 /70 10 100
ETA-CE Certified item
Fire Resistance Certified item
Seismic assessment: performance category C2-C1
European Technical Assessment
European Technical Assessment
ETA-11/0336 – ETAG 001 – PART 1 – 3 and ANNEX E
Option 1 – cracked and non-cracked concrete
Seismic assessment – performance category C2-C1
Fire Resistance
Fire Resistance
R120
CrVI free Zinc Plated (in compliance with ROHS)
For heavy duty fixings in cracked and non-cracked concrete of strength class min.C20/25 and max C50/60, according to European Technical Approval (ETA – CE, DoP)
Performance Category C2 and C1 for use under seismic action, according to ETAG 001 – ANNEX E (Ø16 mm)
Fire resistance R30-R120 according to Technical Report TR 020
Through fixing (in-place anchorage)
Torque control is not required
Waiting time for loading after installation is not required
Also suitable for lower than C20/25 concrete, or for heavy masonry or stones (all the above mentioned cases are NOT covered by ETA, so special tests are required before the installation)